• Home
  • Products
  • 35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18)

35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18)

35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18)

35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18) for power substations and indoor power distribution. Custom voltage, capacity, enclosure, cooling and accessories are available for project supply.

Send your transformer requirements. We will reply soon.

    Description

    35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18)

    35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18) is designed for reliable power distribution in power substations, industrial plants, commercial buildings, renewable energy projects and infrastructure power distribution. As a 35kV SCB dry type transformer, it provides oil-free insulation, stable operation and flexible configuration for projects that require safety, efficiency and long-term reliability.

    Key Features

    • Designed for medium-voltage power distribution where fire safety and low maintenance are important.
    • Cast resin dry-type structure supports stable operation in indoor substations and demanding environments.
    • SCB13, SCB14 and SCB18 options help match project targets for efficiency and loss performance.
    • Custom voltage ratio, enclosure protection, temperature control and accessories are available.

    Technical Parameters

    Basic Models SCB10 / SCB11 / SCB12 / SCB14 / SCB18
    Transformer Structure Epoxy resin cast dry-type transformer, copper winding, low-voltage foil winding
    Rated Capacity 50kVA-25000kVA; common ratings include 50, 100, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 4000 and 5000kVA
    Rated Frequency 50Hz standard; 60Hz can be customized
    Phase Three phase
    Installation Indoor installation; IP20 standard, IP40 optional
    High Voltage 35kV; maximum operating voltage 40.5kV
    Low Voltage 0.4kV / 10kV; 35/0.4kV is common
    Tap Range +/-2 x 2.5%, off-circuit tap changer
    Connection Group Dyn11 preferred; Yyn0 and Yd11 available
    Thermal Class Class F 155 C; Class H 180 C optional
    Insulation Level 35/0.4kV LI170AC70 / AC5
    Insulation Level 35/10kV LI170AC70 / LI75AC35
    Partial Discharge <=5pC standard
    Pollution Level Class III (d)
    Cooling Method AN natural air cooling / AF forced air cooling
    Temperature Rise Limit Winding 100K for Class F; core and structural parts 80K

    Loss, Mechanical and Operating Reference

    Short-Circuit Impedance 6%-8%; 7%-8% for larger capacity designs
    Short-Circuit Withstand High-voltage side withstand up to 20kA for 4 seconds, subject to final design
    Noise Level 50-65dB under AN; 55-70dB under AF
    Reference Weight 1000kVA about 5500kg; 2000kVA about 8500kg; 4000kVA about 13000kg
    Reference Dimensions 1000kVA: 2000 x 1200 x 2000mm; 2000kVA: 2300 x 1400 x 2200mm; 4000kVA: 2600 x 1600 x 2500mm
    Operating Altitude <=1000m standard; derating is required above 1000m
    Ambient Temperature -25 C to +40 C
    Loss Note SCB14 and SCB18 models can be configured for lower loss performance according to the required efficiency level.

    Application Scope

    • Transmission and distribution connection for 35kV substations, reducing regional grid voltage and connecting 35kV high-voltage grids with 10kV medium-voltage networks.
    • Main step-down substations for steel, chemical, metallurgy and other heavy industrial enterprises.
    • Primary distribution systems for large industrial parks and centralized power rooms.
    • Step-up or step-down distribution in photovoltaic power stations and wind farms that require 35kV grid connection.
    • 35kV distribution nodes in urban grid renovation and new regional grid construction projects.

    Available Custom Options

    • Rated capacity and voltage ratio
    • Vector group, impedance and frequency
    • IP enclosure, cooling fan and temperature control system
    • Terminal arrangement, accessories, test reports and export packaging

    Scope of application: 1. Power transmission and distribution link: 35kV substation, distribution voltage reduction of regional power grid, connecting 35kV high-voltage power grid and 10kV medium voltage power grid. 2. Large industrial scenarios: general step-down substations for heavy industrial enterprises such as ste

    FAQ

    What is 35kV SCB Series Dry-Type Transformer (SCB13, SCB14, SCB18) used for?

    It is used for power substations, industrial plants, commercial buildings, renewable energy projects and infrastructure power distribution, especially where oil-free power distribution and safer indoor installation are preferred.

    Can the transformer be customized?

    Yes. Voltage ratio, rated capacity, enclosure protection, cooling method, accessories and project standards can be customized.

    Which cooling methods are available?

    AN natural air cooling is available as standard, and AF forced air cooling can be configured when higher load capability or project conditions require it.

    What information is needed for a quotation?

    Please provide capacity, voltage ratio, frequency, vector group, installation environment, required standard, quantity and destination country.

    Additional information

    Voltage Range

    35kV

    Application

    power substations, industrial plants, commercial buildings, renewable energy projects and infrastructure power distribution

    Insulation System

    Cast resin / dry-type insulation system

    Cart (0 items)
    PROJECT INQUIRY

    Get a Free Quote

    Tell us your transformer requirements. Our team will recommend a suitable solution.

      Not sure about the exact specifications? Send us your application requirements and our engineers can help.

      ✓ Factory Direct ✓ OEM / ODM ✓ 6kV–110kV ✓ Global Supply